OPERATORS MANUAL
ORION II
Orion II 500-10000 Operators
Page 8 of 95
Manual Part no: DOMAON0100 Issue A
April 2008
2.6 ELECTRODE GASSES
The CEDI unit produces small amounts of gas containing hydrogen which is flammable and should
be vented to a point outside the building. The gas can be removed from the unit in a gas separator
and the gas outlet from the separator vented outside the building.
If a gas separator is not supplied the unit should be installed in a room provided with adequate
ventilation, see below.
2.7 VENTILATION
The unit should be operated in a properly ventilated room to prevent overheating and to remove any
traces of hydrogen not removed by the gas separator. As a general guideline the air in the room
should be changed four times per hour.
IF IN DOUBT FURTHER INFORMATION ON SAFETY CAN BE OBTAINED FROM YOUR LOCAL
VEOLIA WATER SERVICE DEPARTMENT