K5/K5N Vacuum Packaging Machine
Setting up the machine
2002-04-25
Art. no. 519.339 DE
Page 1 6/55
5 Setting up the machine
5.1
Criteria for the installation site
It must be set up in a dry, well-ventilated room. The machine must be protected against the continuous
splashes, jets and gushes of water.
5.2
Foundations
A horizontal industrial floor is adequate as a foundation. Slight vibrations may carry from the vacuum
pump to the floor.
5.3
Ambient temperature
The machine is designed to be operated at an ambient temperature of b10°C and +35°C. At
temperatures below 10°C, the starting current for the vacuum pump rises and the fuses may blow.
5.4
Safety space
Leave a space of at least 50 cm right around the machine for operating and maintenance work. There
must be clearance of at least 10 cm above the lid when it is opened wide.