Installation, Operating & Maintenance Instructions
Series 650 DN 100-250 (I.D. 4“ - 10”), RS485
VAT Vakuumventile AG, CH-9469 Haag, Switzerland
Tel ++41 81 771 61 61 Fax ++41 81 771 48 30 Email
www.vatvalve.com
271149EA
2007-06-12
49/77
Command
Acknowledgement
(within 10ms after reception of command)
Inquiry function
Description
Get [i:70][CR][LF]
[i:70][xxxxxxxxxx][CR][LF]
THROTTLE CYCLE
COUNTER
data length 10 characters
xxxxxxxxxx number of throttle cycles
This function returns the number of throttle cycles. A movement from max. throttle position
to open back to max. throttle position counts as one cycle. Partial movements will be added
up until equivalent movement is achieved.
Get [i:71][CR][LF]
[i:71][xxxxxxxxxx][CR][LF]
ISOLATION CYCLE
COUNTER
data length 10 characters
xxxxxxxxxx number of isolation cycles (only series 65 and 61.5)
This function returns the number of isolation cycles. Each closing of the sealing ring counts
as one cycle.
Get [i:72][CR][LF]
[i:72][xxxxxxxxxx][CR][LF]
POWER UP COUNTER
data length 10 characters
xxxxxxxxxx number of power ups
This function returns the number of control unit power ups.
Get [i:80][CR][LF]
[i:80][abcdefgh][CR][LF]
HARDWARE
CONFIGURATION
data length 8 characters
a
0 = Power Failure Option (PFO) not equipped
1 = Power Failure Option (PFO) equipped
b
0 = ±15V sensor power supply (SPS) not equipped
1 = ±15V sensor power supply (SPS) equipped
c
8 = RS485 Interface without analog outputs
9 = RS485 Interface with analog outputs
d
1 = 1 sensor version, 2 = 2 sensor version
efgh
reserved, do not use
This function returns the hardware configuration of the device.
Get [i:82][CR][LF]
[i:82][xxxxxxxx][CR][LF]
FIRMWARE
CONFIGURATION
data length 8 characters
xxxxxxxx
firmware version, e.g. 650P1D00
This function returns firmware version of the device.
Get [i:83][CR][LF]
[i:83][xxxxxxxxxxxxxxxxxxxx][CR][LF]
IDENTIFICATION
data length 20 characters
xxx...xxx
identification code, e.g. /0001/, unused digits are filled up with
spaces
(20
hexadecimal)
This function returns an identification code. This code is unique for each valve and allows
tracing.