D e s c r i p t i o n
Required tool
39. If necessary adjust pendulum plate:
a. Move pendulum plate a little towards
open (e.g. position 1% of full stroke)
b. Use adjustment screw at flange side
of actuator (1 turn clockwise adjusts
pendulum plate by about 3mm
towards open).
c.
Restart valve in menu
„System/Recovery‟
d. Check pendulum plate position
according step 38 and redo
adjustment procedure if necessary.
Adjusting screw mounted either in actuator
position «B1 standard» or «B2 option»
Allen wrench
2mm
40. Clean the valve sealing surface
Lint-and dust-free
towel a little
soaked with
isopropyl alcohol
41. Clean the valve bonnet o-ring
Lint-and dust-free
towel
42. Mount valve bonnet.
Tightening torques for bonnet
screws, see in table to the right.
Max. torque 6 Nm
Allen wrench
5mm