![VAT 650 AP Series Скачать руководство пользователя страница 19](http://html1.mh-extra.com/html/vat/650-ap-series/650-ap-series_installation-operating-and-maintenance-instructions_855907019.webp)
Installation, Operating & Maintenance Instructions
Series 650 DN 100-
250 (I.D. 4“ - 10”), DeviceNet
VAT Vakuumventile AG, CH-9469 Haag, Switzerland
Tel +41 81 771 61 61 Fax +41 81 771 48 30 [email protected] www.vatvalve.com
266341ED
2012-07-13
19/79
2.6.5 Power and sensor connection ( 15 VDC sensors) with optional SPS module
[650 . . - . .
A
. - . . . . / 650 . . - . .
C
. - . . . . versions only]
Note:
Use shielded sensor cable(s). Keep cable as short as possible, but locate it away from noise sources.
Connect the 15 VDC sensors at DB
–15 female sensor connector exactly as shown in the drawing above.
Do not connect other pins that may damage sensors, power supply or controller!
Connector: Use only screws with 4-40UNC thread for fastening the connectors!
Low range sensor may be connected
to sensor 1 or sensor 2 input.
Do configuration accordingly.
Pins 4 and 8 must be bridged for operation!
An optional switch would allow for motor
interlock to prevent valve from moving.