Installation, Operating & Maintenance Instructions
Series 650 DN 100-
250 (I.D. 4“ - 10”), DeviceNet
VAT Vakuumventile AG, CH-9469 Haag, Switzerland
Tel +41 81 771 61 61 Fax +41 81 771 48 30 [email protected] www.vatvalve.com
266341ED
2012-07-13
27/79
3.5 Display information
There is a 4 digit display located on the panel.
It displays configuration, status and position
information. For details see following tables.
Power up:
Description
Digit 1
Digit 2
Digit 3
Digit 4
At first all dots are illuminated then
configuration is displayed:
Firmware version [e.g. 1E00]
(1
st
information for about 2s)
Controller configuration
(2
nd
information for about 2s)
SYNC
indicates that power up
synchronization is running.
In case
D C
or
D999
is displayed,
motor interlock is active. Refer to
«Safety mode» for details.
If valve is closed (isolated) display
shows alternately
C C
and
INIT
.
Syncronization will be done when
first movement command is
received.
1
E
0
0
4
= DeviceNet
®
Interface
0
= basic
1
= with SPS
1)
2
= with PFO
2)
3
= with SPS
1)
and PFO
2)
1
= 1 sensor version
2
= 2 sensor version
S
Y
N
C
1) SPS = optional ±15 VDC Sensor Power Supply module
2) PFO = Power Failure Option
Display
1 2 3 4