Example of PRESSURE and SENSOR READING allocation:
Above picture shows a 2 sensor system. In this configuration sensor 2 covers low range (100 mTorr) and sensor 1
covers high range (1 Torr).
Switchover between sensors is done automatically according to «Pressure control operation with 2 sensors».
0
-10V
High range
sensor
Low range
sensor
0
-10V
SENSOR 1 READING
0
– 10’000
100 mTorr
1 Torr
0 mTorr
SENSOR 2 READING
0
– 10’000
PRESSURE
0
– 10’000