79
7532
Troubleshooting
9.2
System error messages
Code
Description
Possible cause
Remedy
A102
checksum error
general reset & new
calibr.required
device has been powered off
before data could be stored;
emc problem; E²PROM defect
reset;
avoid emc problem; if
alarm prevails after reset,
exchange electronics
W103
initialising - please
wait
E²PROM storage not yet
finished
wait some seconds; if
warning prevails, exchange
electronics
A106
downloading please
wait
processing data download
wait until warning
disappears
A110
checksum error
general reset & new
calibr.required
device has been powered off
before data could be stored;
emc problem; E²PROM defect
reset;
avoid emc problem; if
alarm prevails after reset,
exchange electronics
A111
electronics defect
RAM defective
reset;
if alarm prevails after
reset, exchange electronics
A113
electronics defect
ROM defective
reset;
if alarm prevails after
reset, exchange electronics
A114
electronics defect
E2PROM defective
reset;
if alarm prevails after
reset, exchange electronics
A115
electronics defect
general hardware problem
reset;
if alarm prevails after
reset, exchange electronics
A116
download error
repeat download
checksum of stored data not
correct
restart download of data
A121
electronics defect
no factory calibration existant;
E²PROM defective
contact service
W153
initialising - please
wait
initialisation of electronics
wait some seconds; if
warning prevails, power off
device and power on again
A155
electronics defect
hardware problem
reset;
if alarm prevails after
reset, exchange electronics
A160
checksum error
general reset & new
calibr.required
device has been powered off
before data could be stored;
emc problem; E²PROM defect
reset;
avoid emc problem; if
alarm prevails after reset,
exchange electronics
A164
electronics defect
hardware problem
reset;
if alarm prevails after
reset, exchange electronics
A171
electronics defect
hardware problem
reset;
if alarm prevails after
reset, exchange electronics
A231
sensor 1 defect
check connection
HF module or electronics
defective
exchange HF module or
electronics
Table 3: System error messages
Содержание 7532
Страница 21: ...21 7532 Mounting Preparation for the installation of the Varec UNI flange R532xx 00 00 06 en 002...
Страница 31: ...31 7532 Operation 5 Operation 5 1 Quick operation guide...
Страница 44: ...Operation Radar Tank Gauge 44 Installation and Operations Manual...
Страница 46: ...Commissioning Radar Tank Gauge 46 Installation and Operations Manual 6 3 Basic Setup...
Страница 72: ...Commissioning Radar Tank Gauge 72 Installation and Operations Manual...
Страница 74: ...Maintenance Radar Tank Gauge 74 Installation and Operations Manual...
Страница 76: ...Accessories Radar Tank Gauge 76 Installation and Operations Manual...
Страница 77: ...77 7532 Troubleshooting 9 Troubleshooting 9 1 Troubleshooting instructions...
Страница 91: ...91 7532 Appendix 11 Appendix 11 1 Operating menu HART Display modul ToF Tool...
Страница 94: ...Appendix Radar Tank Gauge 94 Installation and Operations Manual 11 2 Operating matrix HART Commuwin II...
Страница 105: ...7532 IOM027FVAE0804 105 Notes...