101
7532
Appendix
11.4.5
Particularities in "approved" operation
The 7500 RTG level radar is set to custody transfer mode after commissioning using a
custody locking switch (see page 36). The position of the custody locking switch is
secured and sealed using the sealing pin.
During custody transfer measurement, all custody transfer-relevant functions for
operation are automatically locked, so that the device software can not be used, either
via local operation or via digital communication settings. This locked status is displayed
by the key symbol ( ).
7500 RTG radar devices continuously monitor the compliance with accuracy
requirements for custody transfer measurements according to OIML R85. If, for
example, the accuracy cannot be maintained due to quick surface movements, this is
reported via a separate alarm in the local display (displays "#" symbol) and via digital
communication.
11.4.6
Definition of terms
For definitions and procedures please refer to the following documents:
• Manual of Petroleum Measurement Standards, Chapter 3 - Tank Gauging,
Section 1.B - Standard Practice for Level Measurement of Liquid Hydrocarbons in
Stationary Tanks by Automatic Tank Gauging, American Petroleum Institute, second
edition, 2001
• OIML R 85, Organisation Internationale de Métrologie Légale, International
Recommendation R 85, edition 1998 (E)
Содержание 7532
Страница 21: ...21 7532 Mounting Preparation for the installation of the Varec UNI flange R532xx 00 00 06 en 002...
Страница 31: ...31 7532 Operation 5 Operation 5 1 Quick operation guide...
Страница 44: ...Operation Radar Tank Gauge 44 Installation and Operations Manual...
Страница 46: ...Commissioning Radar Tank Gauge 46 Installation and Operations Manual 6 3 Basic Setup...
Страница 72: ...Commissioning Radar Tank Gauge 72 Installation and Operations Manual...
Страница 74: ...Maintenance Radar Tank Gauge 74 Installation and Operations Manual...
Страница 76: ...Accessories Radar Tank Gauge 76 Installation and Operations Manual...
Страница 77: ...77 7532 Troubleshooting 9 Troubleshooting 9 1 Troubleshooting instructions...
Страница 91: ...91 7532 Appendix 11 Appendix 11 1 Operating menu HART Display modul ToF Tool...
Страница 94: ...Appendix Radar Tank Gauge 94 Installation and Operations Manual 11 2 Operating matrix HART Commuwin II...
Страница 105: ...7532 IOM027FVAE0804 105 Notes...