46
FAS-402-CH/ FAS-602-CH Series Operating Instructions Ver. 1.05E
[Replace when] The heating element breaks often, the
seal becomes messy, etc.
[Essential tools] Phillips screwdriver, Scissors,
Industrial alcohol (Ethanol)
1
Remove the fluoro glass sheet and heating
element.
2
Remove the glass tape and Sarcon sheet
mounted under the heating element.
3
Cut the new Sarcon sheet 2mm longer than the
sealing area length on both sides. Adhere it to
the real receiving plate.
4
Cut the new glass tape and adhere it over the
Sarcon sheet. The glass tape length has to be
5mm longer than the sealing area so it covers
the electrodes.
The glass tape and Sarcon sheet are sold individually or
included in the maintenance parts kit.
9-5 Replace glass tape (19mm:
pressure lever/ 25mm: seal
receiving plate) and Sarcon sheet
Caution
If the glass tape and/or Sarcon sheet are
damaged, it will cause the insulation failure
and bad sealing. Please replace the glass
tape and Sarcon sheet if necessary.
Attention
Applying the Sarcon sheet and glass
tape to a surface with adhesive
residues will negatively affect the
sealing surface.
Attention
If the adhesive of the Sarcon sheet is
weak when replacing the glass tape,
please replace the Sarcon sheet as
well.
Sarcon sheet
Glass tape
Seal area length
Electrode
Adhere the
glass tape over
the Sarcon
Sheet.
Fold along both
edges and
adhere to the
sides of the
seal bars.
About 2mm
About 2mm
About 5mm