![Van Der Stahl FAS-402-CH Series Скачать руководство пользователя страница 18](http://html1.mh-extra.com/html/van-der-stahl/fas-402-ch-series/fas-402-ch-series_operating-instructions-manual_3337610018.webp)
18
FAS-402-CH/ FAS-602-CH Series Operating Instructions Ver. 1.05E
6'56
After setting all the conditions at the control unit, hold
the bag by both hands and stretch it tight. Set the bag
between seal levers. (Insert the vacuum nozzle into the
bag if necessary.) Depress the foot switch to proceed the
operation. Please find the most suitable conditions as
you do test sealing.
1
After finishing operation, always turn OFF the
power switch.
2
Shut off the circuit breaker.
The machine will stop completely.
Compressor and cooling fan will stop running.
Unplug the power outlet in the case of not using the
machine for a while.
After use, please clean up the parts such as dry filter.
Please refer to “9 Replacing the routine maintenance
parts” for the detail.
After the vacuuming -if the vacuuming is set-, heating
and cooling cycle has finished, the pressure lever
returns to the initial position, and the sealing is
complete. If a sealing is not clean enough, adjust the
heating time or heating/cooling temperature. Also adjust
the vacuuming if necessary.
7-11 Turn OFF the circuit breaker and
power switch
7-12 Inspection after operation
7-9 Test sealing
7-10 Finish sealing