geoTHERM exclusive VWS 0020051614_00 installation instructions
6.4.1
Unblocked mains supply (Electroplan 1)
L
N
PE
L
N
L
L
L
L
N
N
N
N
S
S B B
L
L
:
:
2 kW
4 kW
+
+
+
1
230 V / 50 Hz
Fig. 6.2 Unblocked mains feed (supplied configuration)
Key to Fig. 6.2
Pump
Compressor
Controller
Auxiliary heater
:
:
2 kW
4 kW
Alternatively, you can set the aux-
iliary heating from 4 kW to 2 kW
power by disconnecting the bridg-
ing line.
This is how the heat pump is wired when delivered.
The heat pump is connected to the mains on a single
tariff (one consumer meter) (
1
). The power company re-
serves the right to switch off the compressor and the
auxiliary heating as required by means of a ripple con-
trol signal. The duration and frequency of the shut-
downs is determined by the company, or should be clari-
fied with them.
• Connect the power supply to the principal mains feed
(
1
).
• Connect the ripple control signal relay to terminal 13,
"EVU" (see Fig 6.6), if required by the power compa-
ny. The heat pump is blocked with this signal when the
contact is closed.
You will find an overview of the complete wiring dia-
gram in the appendix.
Electrical installation 6