Installation instructions for geoTHERM exclusive VWS 0020051614_00
68
Display shown
Description
Factory setting
Tool
A6
Component Test 2
Component
VR 60
Addr. 4
Actuators
Off
Sensors
VF a
29 °C
Select
The display only appears is several heating circuits
and at least one VR 60 are installed.
You can check the actuators for the connected ac-
cessories with the component test 2. This interven-
tion lasts for a maximum of 20 minutes and ignores
current controller inputs during this time. After-
wards, the heat pump reverts to its previous operat-
ing condition.
Tool
A7
Ventilation
Venting prog
Off
Venting prog.: The brine pump alternates between
50 minutes operating and 10 minutes off.
24 hours of intermittent operation of the brine pump
and the circulation pump, and also UV1 and the cool-
ing UV/mixer if necessary.
—
Tool
A8
Outside temperature
0.0 K
DHW sensor SP
0.0 K
T Flow Mix.OffsetVF2
0.0 K
Buffer sensor RF1
0.0 K
Manual adjustment of the displayed temperatures.
Offset adjustment range
Outside temperature
: +/- 5 K, step size 1.0 K.
all others: +/- 3 K, step size 0.5 K.
Flow sensor VF2 temp.
is always displayed.
Internal sensors can only be changed via vrDIALOG;
buffer sensors and cylinder sensors only if the corre-
sponding hydraulics are installed.
Turn the right hand dial to display more sensors.
Setting the
display contrast
(0 – 25).
0 K
0 K
0 K
0 K
16 (Display)
Installation completed
A9
Exit mode?
>yes
>Settable values
Note regarding initial commissioning:
Do not set "Exit mode" to "YES" unless you are sure
that everything has been set correctly.
Once you have confirmed with "YES", the controller
switches to the graphics display. The heat pump
starts under its autonomous control system.
This menu will not appear again once
YES
has been
selected.