Installation instructions for geoTHERM exclusive VWS 0020051614_00
66
Display shown
Description
Factory setting
Menu A: Installation assistant
You will be guided through the Installation Assistant,
Menus A1 and A2, during the initial commissioning of
the heat pump.
The Installation Assistant appears automatically dur-
ing initial commissioning.
Installation
A1
Language selection
Language
>GB English
>Select
Language
: Set the local language
During the initial installation the controller always
starts with this menu (Installation Assistant).
Installation assistant
A2
Hydraulic scheme
3
Heat pump type
5
Electric Wiring Diagram
1
Accept change
Yes
>Select
The hydraulic and electro plans must be set by the
installer during initial commissioning.
The heat pump type has already been set at the fac-
tory and may not be changed!
Hydraulic plan:
6 = no buffer cylinder, with DHW cylinder
8 = with buffer cylinder, with DHW cylinder See
Fig. 6.10 and Fig. 6.11.
Heat pump type:
Type Description
32
VWS 63/2 230 V
33
VWS 83/2 230 V
34
VWS 103/2 230 V
Electroplan:
1 = all on the high tariff (see Fig. 6.2).
2 = low tariff for the compressor (see Fig. 6.3).
3 = low tariff for the compressor and electric auxilia-
ry heating (see Fig. 6.4).
Accept change:
Yes/No;
"Yes" means that all the set values will be saved.
Table 8.4 Parameters that can be set in the Code level (cont.)