Installation instructions for geoTHERM exclusive VWS 0020051614_00
54
8.6
Code level sequence diagram
HK 2
C2
Art
AT-Abschaltgrenze
21 ºC
Parameters
Fixed value
> Values can be set
HK 2
C2
Art
AT-Abschaltgrenze
21 ºC
Parameters
Fixed value
> Values can be set
HK 2
C2
Type
Max limit outs.temp.
21 ºC
Parameters
Fixed value
> Values can be set
Code layer
change
C1
Code number:
0 0 0 0
Accept change?
No
>Adjust numeric character
HK 2
C2
Type
Heating curve
> 0,80
Max limit outs.temp.
21 ºC
Parameters
Direct circuit
Comp. starts at
-120ºmin
> Set heating curve
HK2
Parameterss
C4
Setpoint flow temp.
41 °C
Current flow temp.
29 °C
Pumpenstatus
OFF
Mischerstatus
OPEN
HK2
Parameterss
C4
Setpoint flow temp.
41 °C
Current flow temp.
29 °C
Pumpenstatus
OFF
Mischerstatus
OPEN
HK2
Parameters
C4
Setpoint flow temp.
41 °C
Current flow temp.
29 °C
Status of pump
OFF
Status hydr. mixer
OPEN
HK2
Information
C4
Setpoint flow temp.
41 ºC
30 ºC
Flow Temp. VF2
OFF
Status of pump
-183ºmin
°mins lag/gain
HK2
Parameterss
C5
Raumaufschaltung
Keine
Fernbedienung JA
23 °C
>Values can be set
HK2
Parameterss
C5
Raumaufschaltung
Keine
Fernbedienung JA
23 °C
>Values can be set
HK2
Parameters
C5
Switch-on room temp.
None
Remote control
YES
23 °C
>Values can be set
Special function
Floor drying
C6
Day
Temp.
HK2: >
1
HK3:
HK4:
0 °C
> Set starting day
Auxilary heater
C7
Aux on during CH
no CH
Aux on during DHW
comfort
ZH Starts at
-600°min
> Values can be set
Legionella protect
C9
Legionella protect
OFF
Legionella start
4:00
> Select
Buffer tank
C3
Setpoint flow temp.
41 °C
T buffer top <VF1>
30 °C
T buffer Bottom <RF1>
25 °C
Information
Cooling
Parameters
C8
Max Flow Setpoint.
22 °C
> Select
*) displays in grey are dependent on the set hydraulic plan
Fig. 8.2 Displays in the Code level