DS1098-019A
25
3.4.3
CAPTURE (CATTURA)
This subsection of the Parameters menu can be used to configure the parameters dedicated to the acquisition of images
in alarm conditions and to the programming of the times during which the function must be active.
3.4.3.1
Capture
The Capture function is used to set the parameters for recording images in an alarm situation. The figure below shows the
possible options.
•
Channel
: selects the channel to configure.
•
Auto Capture:
enables or disables the auto capture feature on the selected channel.
•
Stream Mode:
selects the data stream to be recorded, possible values: Main Stream, Sub Stream.
•
Schedule Interval:
selects the recording time for manual capture (normal), possible values: 5 sec, 10 sec, 30 sec, 1
min, 10 min, 30 min, 1 hour.
•
Alarm Interval:
selects the recording time for auto capture (alarm), possible values: 5 sec, 10 sec, 30 sec, 1 min, 10
min, 30 min, 1 hour.
•
Manual Capture:
enables or disables the manual capture by the user function.
•
Copy
: this is used to copy the current channel settings to another or to all other channels.
3.4.3.2
Capture Schedule
The Capture Schedule function allows you to set the time periods and days of the week when the capture function is
operational.
•
Channel
: selects the channel to configure.
•
Normal:
select to set the time periods when the system will record in manual capture mode
.
•
Motion:
this option is used to define the desired time periods in which automatic motion detection is enabled.
•
Alarm:
this option is used to define the desired time periods in which sensor capture is enabled.
•
Copy
this allows you to copy the current channel settings to another or to all other channels.
Click on the [Save] button when the programming is completed.