W A S H S E L E C T I I
Document Number:
WS21002
122
Document Title:
WSII Operations Manual
menu); the programmed token value is internally multiplied by the number of pulses sent by
the IDX.
(Example: If you have assigned a token value of $.50 under t
he “Cash & Tokens” menu, and
you have four different tokens, each token must be worth a multiple of $.50. or as follows
token 1 = $.50, token 2 = $1.00 token 3 = $1.50 and token 4 = $2.00. As you can see each
token in this example represents numbers that can be divided by $.50.) The Wash Select II
does not keep a separate accounting of each different token your site may have; it just keeps
a running total equal to the total dollar value entered. This total will be reflected on the Wash
Select II accounting report.
To program the IDX to accept a single token, follow the instructions below. If more tokens are
required, refer to Table 23 to get the switch locations for that particular token, and then
depress the push-button the number of times that is equal to the number of pulses to be
output for that token.
1.
Locate the rotary-switch and set it to position 1, 2, 3, or 4.
2.
Press the button immediately to the left of the rotary-switch one or more times
depending on the number of pulses you want that token to send.
3.
Drop six sample tokens through the coin slot one at a time, and verify that the red
light (LED) blinks several times after the last token has been entered.
4.
Reset the rotary-
switch to “0”, and then replace the front cover.
Now assume your token value is set for $1.00. To program the IDX acceptor to accept two
different tokens, token number 1 for $1.00 and token number 2 for $2.00, follow the steps
below.
1.
Set the rotary-
switch to position “1”.
2.
Press the button directly to the left one time.
3.
Drop six sample tokens into the coin slot one at a time, and verify that the light
(LED) blinks several times after the last token is entered.
4.
Now set the rotary-
switch to position “2”.
5.
Press the button directly to the left of the rotary-switch twice (for two pulses or $2).
6.
Drop six sample tokens of the second type into the coin slot one at a time, and
verify that the light (LED) blinks several times after the last token is entered.
7.
Return the rotary-
switch to the “0” position.
8.
Replace the cover.