34
4
CALIBRATION PROCEDURE
34
CALIBRATION P
R
OCEDURE
Chapter
4
Example) When decelerated suddenly with the setting of "4 times"
◇
How to set the rotation stop mode and minimum input rotation speed
1.
Select setting mode 4.
Press
→
three
times.
2.
Set "Rotation stop mode" and "Minimum input
rotation speed".
Press
eight times.
⇒
"Rotation stop settings" is
displayed.
Press
, and the highest digit blinks.
①
Because the highest digit is undefined,
move to the lower digit with
.
②
Select rotation stop mode.
Input the rotation stop mode with
, and
move to the lower digit with
.
(Initial value: 0)
③
Select minimum input rotation speed.
Input the minimum input rotation speed with
, and validate it with
. (Initial value: 0).
3.
Press
twice to go back to the indicated value
display.
Pulse
Display
3000rpm
Final cycle T
T×4
1500rpm
New pulse is detected before T×4 time
Sudden deceleration
1000rpm
(Display held)
Speed
rpm
Angle
rad deg
FNC
Torque
Speed
rpm
Nm
0
0
0
0
《
Setting value
》
H I
LO
HOLD
Minimum input
Undefined
0: 15rpm
1: 10rpm
2: 5rpm
3: 3rpm
4: 2rpm
* 4 times the above,
Rotation stop mode
0: OFF
1: 2 times
2: 4 times
3: 8 times
Undefined
when the pulse rate is
* Fixed as 0 (1rpm)
Angle
rad deg
if UTF/60 pulses,
encoder pulse are
selected or pulses less
* Fixed as 0 (0.1rpm)
when set as low speed
rotation speed
than 600.
"1 pulse".
rotation mode.
RECALL
RECALL
RECALL
ESC