92
10
OPTION INTERFACE
92
OPT
ION INT
E
RFA
C
E
Chapter
10
■
Continuousness / printed transmission mode
Continuousness / printed transmission
Function
Header
Protocol
Main
Sub
Indicated value
&
Status
G
S
*5
*4
*3
*2
*1
S
G
*7
*6
TM380
±
Torque: 5-digit
*8
,
0
1
3
4
5
6
7
8
10
,
2
9
13 14
16 17 18 19 20
15
29 30
32 33 34 35
31
*9
,
12
11
Delimiter
36
+
.
Rotation speed: 5-digit
21 22
24 25 26 27
23
,
28
37
Sign
Sign +
*1
O:
Over load (LOAD, OFL)
S:
Stable
M: Not stable
H:
In holding
N:
RS485 display mode communication error
Priority: N
>
H
>
O
>
(S or M)
*6
H:
ALM HI ON
L:
ALM LO ON
G:
ALM HI and ALM LO OFF
N:
ALM HI and ALM LO ON
Priority: N
>
(H or L)
>
G
*2
0:
Undefined
*7
N:
Near zero OFF
Z:
Near zero ON
*3
Torque unit
Set unit number
*8
H:
HI limit ON
L:
LO limit ON
G:
HI limit and LO limit OFF
N:
HI limit and LO limit ON
F:
Comparison F
Priority: F
>
N
>
(H or L)
>
G
*4
Angle unit
Set unit number
*5
H:
HI limit ON
L:
LO limit ON
G:
HI limit and LO limit OFF
N:
HI limit and LO limit ON
F:
Comparison F
Priority: F
>
N
>
(H or L)
>
G
*9
H:
ALM HI ON
L:
ALM LO ON
G:
ALM HI and ALM LO OFF
N:
ALM HI and ALM LO ON
Priority: N
>
(H or L)
>
G
+
decimal place
+
decimal place
+ or
-
(fixation)
* When communication mode is "Continuous transmission (hold not
synchronized)", only indicated value is not synchronized with hold.
Torque
Rotation speed
Torque
Rotation speed
Use of encoder (F7-1)
Not use:
-------
Use: Sign, 5-digit, decimal place
About the timing for continuous transmission
According to the communication baud rate setting, the continuous transmission
intervals in the case where the communication modes “Continuous” is selected are
as follows:
Communication baud rate
Continuous transmission interval
57600 bps
100
times/sec.
38400 bps
50
times/sec.
19200 bps
25
times/sec.
9600 bps
12
times/sec.
Point