Virhe. Määritä Aloitus-välilehdessä Heading 1, jota haluat käyttää tähän kirjoitettavaan
tekstiin.
36.
EDID Tab
EDID tab enables analyzing and saving the EDID read from the connected Sink device.
There are three basic functions:
•
Read the contents of the EDID of the downstream sink over the DisplayPort link.
•
Load and save EDID data files in the host PC
•
Edit the EDID contents
EDID Files
With
Load…
and
Save as…
you can read and write a hex EDID file from your PC. Please
note that the program does not alter the contents of the EDID file or verify its integrity
during load and save operation.
Note
Currently the EDID Editor does not support Display ID. You can however modify
hex EDID files with the HEX Editor or load and program externally generated hex
EDID files that have Display ID content.
HEX Editor
When EDID content is either loaded from a file or read from the hardware EDID memory,
it is shown in the
EDID Data
panel on the left-hand side of the dialog. You can edit the
EDID contents by typing over the existing values. The altered content is highlighted with
RED
. Please note that Hex Editor itself does not alter the contents of the EDID data or
verify its integrity.
Once you are done with editing the data, you can either save it to an *.ecd file in your PC
with
Save as…
or program it to the hardware EDID memory with
Write
.
Содержание UCD Console
Страница 1: ...UCD Console for UCD 400 User Manual ...