Virhe. Määritä Aloitus-välilehdessä Heading 1, jota haluat käyttää tähän kirjoitettavaan
tekstiin.
56.
The test is judged FAIL if video mode does not match, the first frame in the list is not found
or the CRC of the following frames do not match the provided list.
The test optionally captures the failed frames as bitmap images and stores them into the
hard disc.
Parameters in use
•
Test Timeout (default 100 000 ms)
•
Number of frames to be tested (default 20)
•
Number of iterations
•
Reference width (default 1920)
•
Reference height (default 1080)
•
Reference BPP (default 24)
•
Expected frame rate (mHz)
•
Frame rate tolerance (mHz)
•
Expected color format
Reference CRCs (R, G, B)
Note:
Please note that in order for the TE to maintain the sequence, all CRCs in the
reference frame list should be different.
Link Test Set – DP Rx
Link Training at All Supported Lane Counts and Link Rates
Test requests link training on all supported lane counts and link rates. Each link training
must be successfully completed in order to pass the test.
Parameters in use
Test Timeout (default 5 000 ms)
Max lane count supported by DUT (default 4)
Max lane rate supported by DUT as multiple of 0.27 Gbps.
(valid settings 6, 10 and 20; default 20)
Long HPD pulse duration (default 1 000 ms)
Link training start timeout (default 5 000 ms)
Delay between test cycles (default 3 000 ms)