Virhe. Määritä Aloitus-välilehdessä Heading 1, jota haluat käyttää tähän kirjoitettavaan
tekstiin.
27.
When you refresh the data from the DPCD registers the changed bytes will be highlighted
with gray background.
The fields edited by the user will be highligted with
red
color.
Saving and Loading DPCD Content
You can save the DPCD data in the address areas that you selected for the two windows as
a file in your PC. You can save the content in three alternative formats:
•
Binary
DPCD Fata File
format (*.DPD). This is Unigraf proprietary format. You can
also load the DPCD content stored in this format.
•
Comma Separated Values
(*.CSV) for loading the data to a spreadsheet.
•
HEX Dump
(*.HEX) in a human readable text format.
By Clicking
Save
you will be able to select the location and the format of the file.
By Clicking
Load
you can load DPCD data saved in
DPCD Data File
(*.DPD) format
to the editor.
To program the data into the DPCD registers of UCD-400 Local Sink click
Write
Changes
.
Note
- Writing DPCD data to the DPCD registers of the UCD-400 Local Sink will
potentially affect the status and capabilities of UCD-400 as seen by the upstream
source.
- User control like Link Training or mode changes will modify the content of the
DPCD registers
- During a reboot of UCD-400 the DPCD registers will be returned to their default
values