Virhe. Määritä Aloitus-välilehdessä Heading 1, jota haluat käyttää tähän kirjoitettavaan
tekstiin.
42.
EVENT LOG
Event Logger
(Event Log) vertical tab can be seen on the left edge of the GUI. Event Log is
enabled with
UCD Pro for DP Sink
or
UCD Pro for DP Source
license.
Event Log dialog is divided into two panels: the left panel lists all transactions and the right
panel shows the parsed transaction data for the line selected in the list on the left.
With the
Event Logger
you can capture and evaluate
•
HPD status
•
DP AUX messages
•
DP SDP messages
The left panel lists the transactions with Time stamps, Type indications, Message source,
and raw message data. The right panel lists the content of one message. Messages
belonging together with the selected one are shown in red color.
Start event logging by clicking
Start Capture
and stop it by clicking
Stop Capture.
You can save transactions in binary *.evt Event Log files by clicking
Save
. You can recall
saved Event Log files by clicking
Open
.
By clicking
Report
you can store event logs as html reports to be shared and viewed with
any web browser. You are first asked to indicate the file name and location, then you can
add detailed information about the DUT and the test in free-text
Report information
.
Содержание UCD Console