YK08-0028-DI-002-08
xiv
CAUTION
Do not give the Pump a shock or lay it down. It might impair the Pump
operation.
The rubber leg is attached to the base.In installing, set the pump in horizontal position, and
place it so that there is no rattle.
0.6 Protective Device
The pump is equipped with a three-phase 200V
~
240V (50/60 Hz) / 380V
~
460V (50/60 Hz)
motor.
This motor is not equipped with the protective device. Put an overload protective device to
connect through the motor with the Power Supply. It is imperative to put the overload protective
device under direction of the Electrical Installation Technical Standard (1965, Department of
Trade and Industry decree No. 61). Refer to “3.5 Electric connection” to select the overload
protective device. It is recommended to put together another protective device such as a leakage
breaker.
CAUTION
It is imperative to put the Overload protection device. Otherwise it
would cause the motor burn out and/or fire.