DC Power
【
DC-10/DC-20
】
8. Appendix
73
Command
Transmission data
Acknowledgment data
Command
Command name
Capacity
Data content
Capacity
Data content
0xA5
Micro ARC Shut Down
Time?
2byte
This sends back the MARC interrupting time of
the power supply currently set in DC.
The MARC interrupting time is a fixed value as
follows.
0x01=100us
0x0C=8000us
0x02=150us
0x0D=9000us
0x03=200us
0x0E=10000us
0x04=500us
0x0F=15000us
0x05=1000us
0x10=20000us
0x06=2000us
0x11=25000us
0x07=3000us
0x12=30000us
0x08=4000us
0x13=35000us
0x09=5000us
0x14=40000us
0x0A=6000us
0x15=45000us
0x0B=7000us 0x16=50000us
0xA6
MARC DELY TIME
?
1byte
This sends back the MARC interrupting delayed
time set in DC.
0x01=1us
0x02=2us
~
0x09=9us
0x0a=10us
0xA7
MARC DELY USE?
1byte
This sends back whether the MARC interruption
delayed function is ON or OFF.
0x00=ARC DELAY ENABLE
0x01=ARC DELAY DISABLE
0xA8
HARC SHUTDOWN
TIME ?
1byte
This sends back the HARC interruption time
currently set in DC.
0
~
500ms
500
:
0x10
0xA9
HARC COUNT ?
1byte
This sends back the set number of MARC counts
for switching to HARC set in DC.
1
~
15
15
:
0x01F4
0xAA
HARC JDGE TIME ?
1byte
This sends back the judgment time for switching
HARC set in DC.
1
~
255ms
256
:
0xFF
0xAB
ARC SHUTDOWN
VOLTAGE?
2byte
This sends back the ARC detection voltage level
set in DC.
40
~
500V
500
:
0x01F4
0xAC
ARC SHUTDOWN
CURRENT?
1byte
This sends back the ARC detection current level
currently set in DC.
0
~
200A
200
:
0x00C8