DC Power
【
DC-10/DC-20
】
5. How to Operate
34
・
About FNC button
Pressing together with the FNC button switches to the functions below the button.
ESC
ARC
ENT
RESET
MENU
ERROR
FNC
・
ARC COUNT check
”FNC+ESC”
Pressing the FNC and ESC (ARC) buttons together enables one to check the number of times that
hard arcs occur.
The maximum countable number of times is 99,999,999. Pressing the ESC button returns to the
main screen.
When the breaker is shut off, the counts are reset.
・
ERROR log check
“FNC+MENU”
Pressing the FNC and MENU (ERROR) buttons together enables one to check the log of ERROR
occurrence.
Pressing the ESC button returns to the main screen.
・
ERROR RESET
“FNC+ENT”
Pressing the FNC and ENT (RESET) buttons together resets ERROR. (*Enabled only in the
LOCAL mode)
In addition, when it is reset while the ARC COUNT number is displayed, the number of times that
hard arcs are detected is reset.
5-1-4. About MENU screen
・
Press the MENU button to display the menu screen.
The current hierarchy is displayed in the first line and the selected items in the second line.
CNFG: this is used to change various parameters.
MONI: this enables one to check the number of times that hard arcs are detected, and the
occurrence log of warnings and errors.
FUNC: this is for using and setting the ramp function and the timer.
Pressing the
◄ or ► button and select an item.
The currently selected item blinks. Pressing the ENT button accepts the item.
Содержание DC-10
Страница 88: ......