DC Power
【
DC-10/DC-20
】
4. Description of Functions
16
4. Description of Functions
This section describes various functions of this power supply.
4-1 Name and function of each part
4-1-1. DC power front panel
②
③
④
⑤
①
⑥
⑦
⑧,⑨,⑩,⑪
⑫
⑬
Figure 4-1: DC power front panel
Table 4-1: Name and function on the front of DC power
N
o.
Name
Shape
Function
①
ON
button
LED (Green)
Push button
This lights up with the DC output ON.
In LOCAL: the DC output starts to produced by pressing when INTERLOCK
OK,READY lights up.
In USER: the switch is pressed but there is no response.
②
OFF
button
Push button
In LOCAL mode, the power output is switched to OFF.
During the USER or SERIAL communication, the OFF button is not accepted but
an error can be caused for an emergency stop by holding the OFF button down.
③
Fan inlet
-
Inlet of cooling fan in the power supply
④
ESC/ARC
button
Push button
Back to the previous one along the parameter tree.
Pressing together with the FUNC button shows the effective number of times of
the hard arc process.
⑤
ENT/RESET
button
Push button
Go to the next one along the parameter tree. Decide the set value.
Press together with the FUNC button to reset the FAIL mode.
* Until the error is solved, FAIL LED is not turned off.
⑥
MENU/ERROR
button
Push button
The parameter tree appears.
Press together with the FUNC button to display the error log.
⑦
FUNC
button
Push button
Use in combination with another button.
⑧
△
button
Push button
In the parameter setting, the set value is increased.
⑨
▽
button
Push button
In the parameter setting, the set value is decreased.
⑩
◁
button
Push button
In the parameter setting, the number of digits is increased. In the state where the
parameter tree is displayed, items are selected.
⑪
▷
button
Push button
In the parameter setting, the number of digits is decreased. In the state where
the parameter tree is displayed, items are selected.
⑫
OLED
display
Display
Set output values, output values, and various parameters appear.
⑬
LED
LED (Green)
SETPOINT
This lights up when the output reaches the set value.
LED (Green)
READY
This lights up when there is no FAIL with the interlock
released.
LED (Green)
INTERLOCK
OK
This lights up when the interlock is released.
LED (Orange)
ARC
This lights up when an arc process is carried out.
LED (Red)
FAIL
This lights up when an error occurs.
Содержание DC-10
Страница 88: ......