DC Power
【
DC-10/DC-20
】
8. Appendix
70
Command
Transmission data
Acknowledgment data
Command
Command name
Capacity
Data content
Capacity
Data content
0x87
FAIL
UNIT
NUMBERS?
2byte
If an ERROR is occurred with an power supply unit
connected in M/S manner, the unit generating the
ERROR is replied with this command. The bit
corresponding to the unit stands up. If an ERROR is
occurred in multiple units, all the corresponding bits
stand up.
NO Fail
:
0x0000
MASTER
:
0x0001
SLAVE1
:
0x0002
SLAVE2
:
0x0004
SLAVE3
:
0x0008
SLAVE4
:
0x0010
SLAVE5
:
0x0020
SLAVE6
:
0x0040
SLAVE7
:
0x0080
SLAVE8
:
0x0100
SLAVE9
:
0x0200
SLAVE10
:
0x0400
SLAVE11
:
0x0800
example)
If ERROR occurs in MASTER, SLAVE4 and
SLAVE5, 0x0031 is returned.
0x88
UNIT
FAIL?
1byte
0x00-> Master
0x01-> Slave1
:
0x0B-> Slave11
4byte
Responds the content of the ERROR that has
occurred.
Specify the product to inquire about the contents of
FAIL with 0x88
The bit corresponding to ERROR is set.
If multiple ERRORs occur, all applicable bits are
set.
For details on the ERROR code and the contents of
the ERROR, refer to Table 4-12 in [4-11. Displaying
the ERROR code and WARNING code on the front
panel].
E10x
0x00000001
MODULE ERROR
E21x
0x00000004
CAN TIMEOUT ERROR
E30x
0x00000010
FUSE ERROR
E31x
0x00000020
OVER CURRENT ERROR
E32x
0x00000040
BUS
OC
ERROR
E33x
0x00000080
LARC ERROR
E34x
0x00000100
TEMP ERROR
E35x
0x00000200
FAN ERROR
E36x
0x00000400
SYSTEM POWER ERROR
E37x
0x00000800
CPU ERROR
E38x
0x00001000
CPU ERROR
E3Ax
0x00004000
EMG STOP RUN ERROR
E3Bx
0x00008000
POWER DEPRESSION
E43x
0x00800000
CONNECT ERROR
E3Cx
0x00010000
CPU ERROR
E3Dx
0x00020000
CPU ERROR
E3Ex
0x00040000
MODE MISMATCH
E60x
0x00080000
LEVEL OVER ERROR
E70x
0x00100000
PCB SETTING ERROR
Содержание DC-10
Страница 88: ......