DC Power
【
DC-10/DC-20
】
4. Description of Functions
21
Table 4-8: System power correspondence table at power setting (LEVEL)
Number of 20-
kW units in use: α; Number of 10-kW units in use: β
Output voltage
setting level:
LEVEL 0 to 10V
In V-control
0
~
1500V
※
In I-control
0
~
(α×50
+
β×25)A ex. for one 20-kW units and one 10-kW unit
0
~
(2×50+1×25)A
⇒
0A
~
125A
In P-control
0
~
(α×20
+
β×10)kW ex. for two 20-kW units and one 10-kW unit
0
~
(2×20+1×10)kW
⇒
0kW
~
50kW
* In the USER control and the SERIAL communication control
Use the LEVEL signal at 10.0 Vmax in the P-control, 10.0 Vmax in the I-control and 5.34 Vmax
in the V-control.
If the above-mentioned level is exceeded, ERROR is produced and the output is stopped.
The 1,000V rated output voltage model is 10.0 Vmax in the P-control, 8.00 Vmax in the I-control,
and 6.67 Vmax in the V-control.
4-5. About DC output sequence
The output sequence of this product is as follows.
INTERLOCK
DC ON
t 時間
READY
DC OFF
DC 出力
H
L
H
L
H
L
H
L
OFF
ON
FAIL
H
L
30 ~45ms
30 ~45ms
10ms~20ms
15~20ms
Figure 4-3: DC output sequence
4-6. Description of arc mode function
This power supply can switch between two types of arc parameters A and B predetermined for your
application purposes.
* Do not switch in the DC ON mode. When the parameters are switched, it applies after the warning
process.
The currently selected arc parameter can be confirmed at the upper right of the screen in the ARC
hierarchy of the MENU screen.
The changed set value of each parameter is retained by the currently selected arc parameter.
Retainable parameters are shown in Table 4-9.
Select
Time t
DC output
Содержание DC-10