DC Power
【
DC-10/DC-20
】
8. Appendix
72
Command
Transmission data
Acknowledgment data
Command
Command name
Capacity
Data content
Capacity
Data content
0x96
Output Mode?
1byte
This sends back the output mode set in DC.
Power
:
0x01
Voltage
:
0x02
Current
:
0x03
0x97
Ignition
Voltage
Limit?
2byte
This sends back the ignition voltage of the power
supply set in DC.
800
~
1500V
0x9A
OSC MODE
?
1byte
This sends back the presence of the external units set
in DC.
0x01 =
NONE
0x06 = MFU
0x02 =
A2K
0x07 = MFU_HIGH
0x03 =
A2K_K
0x08 = MFU_SOFT
0x04 =
A2K_LOWM 0x09 = MFU_SMA
0x05 =
A2K_SMA
0x9C
Ramp Enable
?
1byte
This sends back the status whether the Ramp
operating function is ON or OFF.
0x00 : DISABLE
0x01 : ENABLE
0x9D
Ramp time?
2byte
This sends back the Ramp rise time set in DC.
600.00sec →60000
16-bit integers are transmitted.
0x9E
Ramp Time Start Level?
1byte
This sends back the starting value (Level) for starting
Ramp operation.
The current set value is transmitted in 7-bit.
0
~
100%
0xA0
Power Limit?
2byte
This sends back the output power limit of the power
supply currently set in DC.
0
~
240.0kW →2400
2400
:
0x0960
0xA1
Voltage Limit?
2byte
This sends back the output voltage limit of the power
supply currently set in DC.
0
~
800V(NORMAL model)
800
:
0x0320
0
~
1000V
(1000V model)
1000
:
0x03E8
0xA2
Current Limit?
2byte
This sends back the output current limit of the power
supply currently set in DC.
0
~
600.0A →6000
6000
:
0x1770
0xA4
ARC MODE?
1byte
This sends back whether the SET value of ARC set in
DC is A or B.
For arc parameters that can issue a request by the
following 0xA5 to 0xAE, it is the A value if the SET
value set in DC is set to A or the B value if it is set to
B.
0x00 = SET_A
0x01 = SET_B
Содержание DC-10