Command
Transmission data
Acknowledgment data
Command
Command name
Capacity
Description
Capacity
Description
0x21
VOLTAGE LIMIT
2byte
The limit of the output voltage can be set.
The limit value depends on the power supply model.
0
~
800V
(NORMAL model)
800
:
0x0320
0
~
1000V
(1000V model)
1000
:
0x03E8
1byte
STATUS
0x22
CURRENT LIMIT
2byte
The limit of the output current can be set.
The limit value depends on the composition of the
connected power supplies.
A value 10-hold larger than the desired set value.
0
~
600.0A →6000
6000
:
0x1770
1byte
STATUS
0x24
ARC MODE
CHANGE
For the parameters from 0x25 to 0x2E of the ARC
commands below, 2 values of A/B can be can be set. If it
is set to A, setting each ABC parameter stores and
applies the parameter of A.
If it is changed to B, each ABC parameter can be set,
stored, and applied as the settings for B.
Whether the current status is A/B can be confirmed by
the lead command of 0xA4.
0x00 = SET_A
0x01 = SET_B
1byte
STATUS
0x25
MICRO ARC
SHUTDOWN TIME
1byte
The set interrupting time at the MARC detection.
The selectable interrupting time is a fixed value as
follows.
0x01=100us
0x0C=8000us
0x02=150us
0x0D=9000us
0x03=200us
0x0E=10000us
0x04=500us
0x0F=15000us
0x05=1000us
0x10=20000us
0x06=2000us
0x11=25000us
0x07=3000us
0x12=30000us
0x08=4000us
0x13=35000us
0x09=5000us
0x14=40000us
0x0A=6000us
0x15=45000us
0x0B=7000us
0x16=50000us
1byte
STATUS
0x26
MICRO ARC
DELAY TIME
1byte
This is the time after MARC is detected until the
interruption.
The settings are made in steps of 1u.
0x01=1us
0x02=2us
~
0x09=9us
0x0a=10us
1byte
STATUS