DC Power
【
DC-10/DC-20
】
4. Description of Functions
23
・
LOCAL mode
MENU screen on front panel: A or B can be selected in MENU/CNFG/ARC /MODE/SET.
・
HOST/HOST+ mode
See the operating instruction for serial communication separately.
4-7. Description of micro arc function
DC has a micro arc function to quickly detect ARC when it occurs, and interrupt the output and
separate the load.
With the micro arc function, the interruption time and the detection level can be changed on the front
panel or via the SERIAL communication. Optimal arc handling can be performed by changing the
settings depending on the working load.
The use of signals from USER IO PORT enables the loading of micro arc signals.
For instructions on how to set the parameters, see "MARC" in Section 5-1-4.
※電圧検出
レベル
電流検出
レベル
遮断時間
0V
0A
t 時間
電圧
電流
* The parameter for the voltage detection level is expressed as a positive value but the actual output is
negative.
Figure 4-4: Image of waveform when an arc is detected
* Voltage
detection level
Current
detection level
Interruption time
Voltage
Current
Time t