- 35 -
13. Calling up and modifying the preset value setting
Set the preset values. "OUT1, OUT2".
The setting ranges are 0-99999.
The procedure for setting the preset value is described below.
≪Operation of the preset value setting≫
Operation key
Indication
Procedure
A B C D E
1●
2○ 9 9 9 9 9
T○
Press Mode Key for 2 sec. or more.
"OUT1" LED lights up and the present
preset value is displayed.
A B C D E
1●
2○
9
→9→9→9→9
T○ └---←---┘
Shifts the flashing indication to the digit to
the right.
Each time the key is pressed, shifts the
indication to one right..
A B C D E
1●
2○ 9
0
9 9 9
T○
Changes the value of the flashing digit.
Each time Display Key is pressed, the number
goes up by one.
(0→1→……→9→0→……)
A B C D E
1○
2●
9
9 9 9 9
T○
The OUT2 led lights up and the preset
value setting for OUT2 is shown.
Press Shift Key and Dispay Key to set the
desired setting value.
A B C D E
1○
2○ Measured value
T○
After adjusting the setting, use Reset Key to
register it.
The display returns to the readings following
registration.
! < Caution >
* Which of the rate meter or totalizer is the preset values used by must be
selected according to the mode No.9 and the mode No.A.
* The decimal point is interlocked with the mode No.2 for rate meter and the
mode No.8 for totalizer.
* The mode protection function is invalid.
(Please refer to "11. The mode protect function".)
MODE
DISP
RST
▲
MODE