- 18 -
Calculation example of scaling data (setting example)
Example
Arithmetic expression
Arithmetic
expression
In case of " Revolution "
Scaling data=1revolution/pulse
In case of " Speed "
Scaling data=Amount of transfer/pulse
In case of " Flow "
Scaling data=Flow rate value/pulse
〔Ex.1〕
Revolution
Factor →1 revolution/1 pulse = 1
Exp.value"Mode No.2"
0001×10
-0
or 1000×10
-3
"Mode No.1"
※ Please register scaling data of
"the left side" or "the right side".
Proximity Sensor The right side can be adjusted slightly.
〔Ex.2〕
Revolution
Factor →1 revolution/30 pulse=1/30=0.033333
3333×10
-5
↑
" Mode No.1" Exp. value "Mode No.2"
Sensor ※Please register "3333" at
"Mode No.1" and "5" for
The number of gear teeth;30 B at "Mode No.2".
〔Ex.3〕
Speed
Factor →The speed of " Drive roller : 100
φ
" is indicated.
Scaling data = Amount of transfer/pulse
Scaling data = 100×π/30≒10.47197mm
In case of " mm/min" 1047×10
-2
In case of " cm/min" 1047×10
-3
Sensor
In case of " m/min" 1047×10
-5
↑
The number of gear teeth:30 " Mode No.1" Exp. value "Mode No.2"
〔Ex.4〕
Flow
Factor → 7.692mL/pulse
Scaling data = Flow rate value/pulse
In case of " mL/min " 7692×10
-3
In case of " L /min " 7692×10
-6
↑
"Mode No.1" Exp. value "Mode No.2"
Flow
sensor