- 22 -
Mode No. Setting of EXT input and measurement indication
6
A B C D E
6. 0 0
Indicator
0 : Rate meter/totalizer is switched.
1 : Rate meter is fixed.
2 : Totalizer is fixed.
EXT input
0 : Reset
1 : Hold
2 : Inhibit
3 : Indication change
【 Indicator 】
0 : Rate meter/totalizer is switched.
Rate meter/totalizer is switched with Display Key.
1 : Rate meter is fixed.
Rate meter is fixed and indicated.
2 : Totalizer is fixed.
Totalizer is fixed and indicated.
【 EXT input 】
The function of "terminals No. 6-7" can be registered. (selectable)
0 : Reset
Totalizer is made offset value.
When the presetting output (OUT1,2) is output, it is released.
1 : Hold
During input on, "Hold" is indicated the present value.
〔Operating state : flash〕
* Even the state of a hold is calculated by a computer, and
the presetting output is output by calculation.
2 : Inhibit
During input on, "Inhibit" restrains sensor input.
〔Operating state : non flash〕
3 : Indication change
During input on, rate meter/totalizer is switched.
! < Caution >
* When choosing 1 or 2 by an indicator, an indication change
doesn't function.