- 32 -
Mode No. Analog output(option) : Setting of maximum output indication
d
※ Displayed when analog output option is selected (AI/AV3-5 type).
A B C D E
d.1 0 0 0
Indication value
0001-9999
(Do not specify 0000.)
Set an indication value of the time when the analog output is
maximum.
Set a value in four digits, neglecting the decimal point.
For example, both 500.0 and 50.00 are all right.
(It sets as "5000" in this case.)
〔Ex.〕The settings in a case where the analog output is
synchronized with the rate reading, with a maximum output
when the reading is 5000, would be as follows.
A B C D E
C. 0 0
C :
0〔Rate meter (Synchronized with the indication value .)〕
E :
0〔Digit selection (Right 4 digits)〕
A B C D E
d.5 0 0 0
B-E〔Setting of maximum output indication : 5000〕
! < Caution >
* Even if the indication value goes over the indication value
setting of analog maximum output, it outputs the setting of
analog maximum output indication value.
The limited on 102.4%.
* When setting mode No. d as (0000), an analog output is
always 102.4%.
* If the indication value goes over the indication value setting
of analog maximum output, the limit reaches to 102.4%.
After that, it outputs by the limited value (102.4%).
* If it's always overflow indication in spite of rate meter and
totalizer, it always outputs by the limited value (102.4%).
〔Ex.〕
When it will be making the overflow indication by
setting of the biggest indication and the left 4 digits at
"Mode No.C, d", it'll be 102.4% immediately.