- 11 -
7. Names and functions of components on front
Fig.7-1
1. Display unit(Red)
Measurement state : A measured value is indicated.
Setting state:
A・・・・・ Mode No. is indicated.
B to E・・・The present set value is indicated.
: When preset value setting indicates the preset value.
: When offset value setting indicates the offset value.
: It indicates
“
L-oFF
”
and
“
L-on
”
at the time of mode protect
function setting.
: AnA, An-1-2 and the present bit value are indicated at the
time of analog output adjustment mode setting.
2. Mode Key
Turning on : When a power supply is supplied while is pushing
down Mode Key, a test mode functions is called.
(A stop of the test mode function is power supply off.)
Measurement state : When Shift Key is pressing for 2 sec. or more,while is
pushing down Mode Key, mode setting is called.
: When Mode Key is pressing for 2 sec. or more, preset
value is called.
: When Display Key is pressing for 2 sec. or more,
while is pushing down Mode Key, offset value setting is called.
Setting state : Switch mode No. (1→2→3……9→A→b→C→d→1)
: OUT1,2 is switched at the time of preset value setting.
: An-1-2 is switched at the time of analog output
adjustment mode setting.
A
B
C
D
E
1.Display unit(Red)
2.
3.
4.
5.
8.Totalizer LED(Green)
6.Preset output "OUT1" LED(Orange)
7.Preset output "OUT2" LED(Orange)
MODE