9. Initial setting values and initialization
If the specifications desired by the user are requested prior to shipment,
the meter will be set these settings.
Otherwise, the regular factory settings are shown below.
Value setting of each mode Table.9-1
Mode No.
Initial setting
Notes
Mode contents
A
B C D E B C D E
1.
1 0 0 0
Setting of scaling data
2.
3 0 1 1
Setting of Exp. value, least significant digit,
the unit time and the decimal point
3.
0 2. 0 -
Setting of the sampling time
4.
0
0 0
-
Setting of the moving average range
5.
0 2. 0 -
Setting the auto-zero time
6.
0 0 -
-
Setting of EXT input and measurement indication
7.
1 0 0 0
Setting of scaling data
8.
3 0 1 0
Setting of Exp. value,reset time,
overflow indication and the decimal point
9.
0 0 0 0
Setting of OUT1 preset output
A.
0 0 0 0
Setting of OUT2 preset output
b.
0 0. 0 5
Setting of the synchronization pulse-output
C.
0
0 -
-
Analog output:Setting of measurement choice
(option) and the output digit
d.
1 0 0 0
Analog output:Setting of maximum output
(option) indication
Presetting output set value Table.9-2
Preset value
Initial setting
Notes
A
B
C
D
E
A
B
C
D
E
OUT1
9
9
9
9
9
OUT2
9
9
9
9
9
* With the P1 option, there is no OUT2 preset value setting.
Offset value Table.9-3
Offset
Initial setting
Notes
A
B
C
D
E
A
B
C
D
E
Indication
0
0
0
0
0
〔Initialization〕
Throw power supply in with Reset Key pressed to initialize the settings.
After the initialization, the set values will be as shown in "Table.9-1",
"Table.9-2" and "Table.9-3".
Counter data and the mode protect function are also cleared.
! < Caution >
* Since an initialization changes all existing setting values to the initial
setting values, be sure to record all the setting values before an
initialization.
* In case the computer froze when unusual functioning occurred with
the normal operation, initialize according to the above procedure and
set the desired value again.