- 23 -
Mode No. Totalizer : Setting of scaling data
7
A B C D E
7. 1 0 0 0
Scaling data
0001-9999
(Do not specify 0000.)
Input scaling is performed for the totalizer reading. By specifying
the scaling data and the exponential value (a minus power of 10),
the scaling ratio per pulse can be set.
The exponential value (a minus power of 10) is set in mode No.8.
The setting is the same as that of the mode No.1.
Mode No.
Totalizer : Setting of Exp. value, reset dwell time, overflow
indication and the decimal point
8
A B C D E
8. 3 0 1 0
Decimal point
0 :
0.000
0
1 :
000
0.0
2 :
00
0.00
3 :
0
0.000
4 : 0.0000
Overflow indication
0 : 99999 flashing
1 : 5 digits endless
2 : A place shift is carried out in the 1st excess.
〔" T"LED flashes on and off. 〕
Furthermore, when exceeded :
99999 flashing.
Reset time
0 : 2 sec.
1 : Immediate at (ON edge)
Exp. value (exponent 10
-n
)
n=0-9
【 Exp. value 】
The magnification per 1 pulse is decided at registered property of
"Mode No.7" and "Exp. value".