9.2
Detailed Object Specifications
9.2.1
Object 6040
h
: Control Word
This object indicates the received command controlling the power drive system finite state automaton
(PDS FSA). The CiA-402 state machine can be controlled using this object. Please refer to figure
for
detailed information.
Structure of the Control Word
15
11
10
9
8
7
6
4
3
2
1
0
nu
r
oms
h
fr
oms
eo
qs
ev
so
MSB
LSB
Legend: nu=not used; r=reserved; oms=operation mode specific; h=halt; fr=fault reset; eo=enable opera-
tion; qs=quick stop; ev=enable voltage; so=switch on.
Table 273: Structure of the Control Word in hm Mode
Operation Mode specific Bits in hm Mode
Bit
Name
Definition
4
Homing operation start
1: start homing; 0: stop homing
8
Halt
Not supported.
Table 274: Operation Mode specific Bits in hm Mode
Command Coding
Command
Bits of Control Word
Transitions
Bit 7
Bit 3
Bit 2
Bit 1
Bit 0
Shutdown
0
x
1
1
0
2,6,8
Switch on
0
0
1
1
1
3
Switch on & enable operation
0
1
1
1
1
3, 4
Disable voltage
0
x
x
0
x
7,9,10,12
Quick stop
0
x
0
1
x
7,10,11
Disable operation
0
0
1
1
1
5
Enable operation
0
1
1
1
1
4, 16
Fault reset
0-to-1
x
x
x
x
15
Table 275: Command Coding