TMCM-1160 CANopen® Firmware Manual • Firmware Version V3.20 | Document Revision V2.10 • 2019-JAN-04
23 / 110
3.1.13
Object 1016
h
: Consumer Heartbeat Time
The consumer heartbeat time defines the expected heartbeat cycle time and thus has to be higher than
the corresponding producer heartbeat time configured on the module producing this heartbeat. The
monitoring starts after the reception of the first heartbeat. If the consumer heartbeat time is 0 the
corresponding entry is not used. The time has to be a multiple of 1ms.
Value Definition
Bits
Name
Definition
31. . . 24
Reserved
—
23. . . 16
Node ID
Heartbeat Producer Node ID
15. . . 0
Heartbeat time
Time in 1ms
Table 33: Value Definition (1016
h
)
Object Description
Index
Name
Object Type
Data Type
1016
h
Consumer heartbeat time
Variable
UNSIGNED16
Table 34: Object Description (1016
h
)
Entry Description
Sub-index
Access
PDO Mapping
Value Range
Default Value
0
rw
no
UNSIGNED16
0
Table 35: Entry Description (1016
h
)
3.1.14
Object 1017
h
: Producer Heartbeat Time
The producer heartbeat time defines the cycle time of the heartbeat. The producer heartbeat time is 0 if it
is not used. The time has to be a multiple of 1ms.
Object Description
Index
Name
Object Type
Data Type
1017
h
Producer heartbeat time
Variable
UNSIGNED16
Table 36: Object Description (1017
h
)
©2019 TRINAMIC Motion Control GmbH & Co. KG, Hamburg, Germany
Terms of delivery and rights to technical change reserved.