TMCM-1160 CANopen® Firmware Manual • Firmware Version V3.20 | Document Revision V2.10 • 2019-JAN-04
60 / 110
Object Description
Index
Name
Object Type
Data Type
605E
h
Fault reaction option code
Variable
UNSIGNED16
Table 167: Object Description (605E
h
)
Entry Description
Sub-index
Access
PDO Mapping
Value Range
Default Value
0
rw
no
2
2
Table 168: Entry Description (605E
h
)
5.1.6
Object 6060
h
: Modes of Operation
This object indicates the requested operation mode. Supported operating modes are:
Value Definition
Value
Mode
0
No mode
1
Profile position mode (pp)
2
Velocity mode (vl)
3
Profile velocity mode (pv)
6
Homing mode (hm)
Table 169: Value Description (6060
h
)
The motor will not run when the operating mode is set to 0. It will be stopped when the motor is running
in one of the supported operating modes and the operating mode is then switched to 0.
Object Description
Index
Name
Object Type
Data Type
6060
h
Modes of operation
Variable
SIGNED8
Table 170: Object Description (6060
h
)
Entry Description
Sub-index
Access
PDO Mapping
Value Range
Default Value
0
rw
refer to CiA-402
see table
0
Table 171: Entry Description (6060
h
)
©2019 TRINAMIC Motion Control GmbH & Co. KG, Hamburg, Germany
Terms of delivery and rights to technical change reserved.
Download newest version at