TMCM-1160 CANopen® Firmware Manual • Firmware Version V3.20 | Document Revision V2.10 • 2019-JAN-04
28 / 110
definition, set this bit to inactivate the PDO.
Sub-index 02
h
contains the transmission type of the RPDO. This can be FF
h
or FE
h
for event-driven, or 00
h
or 01
h
for synchronous.
Sub-index 03
h
contains the inhibit time, given in milliseconds. After a TPDO has been sent, it will not be
sent again before the inhibit time has elapsed.
Sub-index 04
h
is not used.
Sub-index 05
h
contains the event timer value in milliseconds. When this is set to a value greater than 0 the
TPDO will be sent repeatedly each time the event timer has elapsed. For example, when this value is set to
250, the TPDO will be sent every 250ms.
Object Description
Index
Name
Object Type
Data Type
1800
h
– 1803
h
Transmit PDO communication parameter
RECORD
TPDO CommPar
1800
h
TPDO 1
RECORD
TPDO CommPar
1801
h
TPDO 2
RECORD
TPDO CommPar
1802
h
TPDO 3
RECORD
TPDO CommPar
1803
h
TPDO 4
RECORD
TPDO CommPar
Table 48: Object Description (1800
h
)
Entry Description
Sub-index
Description
Access
Value Range
Default Value
00
h
Largest sub-index
supported
ro
5
5
01
h
COB-ID
rw
UNSIGNED32
Index 1800
h
: 180
h
+ Node-ID
Index 1801
h
: 280
h
+ Node-ID
Index 1802
h
: 380
h
+ Node-ID
Index 1803
h
: 480
h
+ Node-ID
02
h
Transmission type
rw
UNSIGNED8
Index 1800
h
: FF
h
Index 1801
h
: FF
h
Index 1802
h
: 01
h
Index 1803
h
: 01
h
03
h
Inhibit time
rw
UNSIGNED16
0
04
h
Compatibility
en-
try
ro
UNSIGNED8
0
05
h
Event timer
rw
UNSIGNED16
0
Table 49: Entry Description (1800