TMCM-1160 CANopen® Firmware Manual • Firmware Version V3.20 | Document Revision V2.10 • 2019-JAN-04
49 / 110
Entry Description
Sub-index
Access
PDO Mapping
Value Range
Default Value
0
ro
no
0. . . 255
0
Table 124: Entry Description (2102
h
)
4.2.36
Object 2107
h
: Microstep Resolution Display
This object shows the microstep resolution, set by object 2000
h
(please see section
Object Description
Index
Name
Object Type
Data Type
2107
h
Microstep resolution display
Variable
UNSIGNED8
Table 125: Object Description (2107
h
)
Entry Description
Sub-index
Access
PDO Mapping
Value Range
Default Value
0
ro
no
0. . . 8
8
Table 126: Entry Description (2107
h
)
4.2.37
Object 210B
h
: Step Counter
This object shows the overall number of microsteps done by this motor so far. The value can be read as a
64 bit value (sub-index 3) or split into two 32 bit values (sub-index 1 and sub-index 2).
Object Description
Index
Name
Object Type
Data Type
210B
h
Step Counter
Variable
RECORD
Table 127: Object Description (210B
h
)
Entry Description
Sub-index
Description
Access
PDO Mapping
Value Range
Default Value
1
Lower 32 Bits
ro
no
0. . . ffffffff
h
0
2
Higher 32 Bits
ro
no
0. . . ffffffff
h
0
3
64 Bit Value
ro
no
0. . . ffffffffffffffff
h
0
Table 128: Entry Description (210B