TMCM-1160 CANopen® Firmware Manual • Firmware Version V3.20 | Document Revision V2.10 • 2019-JAN-04
72 / 110
Entry Description
Sub-index
Description
Access
PDO Mapping
Value Range
Default Value
1
Mininmum Position Limit
rw
no
SIGNED32
-2147483648
2
Maximum Position Limit
rw
no
SIGNED32
2147483647
Table 211: Entry Description (607D
h
)
6.1.12
Object 6081
h
: Profile Velocity
This object indicates the configured velocity normally attained at the end of the acceleration ramp during
a profiled motion and is valid for both directions of motion. The profile velocity is the maximum velocity
used when driving to a new position. It is given in internal or user specific units (depending on object
208C
h
, section
Object Description
Index
Name
Object Type
Data Type
6081
h
Profile Velocity
Variable
SIGNED32
Table 212: Object Description (6081
h
)
Entry Description
Sub-index
Access
PDO Mapping
Value Range
Default Value
0
rw
no
SIGNED32
0
Table 213: Entry Description (6081
h
)
6.1.13
Object 6082
h
: End Velocity
This object indicates the configured velocity normally attained at the end of the deceleration ramp during
a profiled motion and is valid for both directions of motion. The end velocity is the velocity used when
reaching the new position. It is given in internal or user specific units (depending on object 208C
h
, section
Object Description
Index
Name
Object Type
Data Type
6082
h
End Velocity
Variable
SIGNED32
Table 214: Object Description (6082
h
)
Entry Description
Sub-index
Access
PDO Mapping
Value Range
Default Value
0
rw
no
SIGNED32
0
Table 215: Entry Description (6082
h
)
©2019 TRINAMIC Motion Control GmbH & Co. KG, Hamburg, Germany
Terms of delivery and rights to technical change reserved.
Download newest version at