TMCM-1160 CANopen® Firmware Manual • Firmware Version V3.20 | Document Revision V2.10 • 2019-JAN-04
7 / 110
Further Characteristics
• SYNC: consumer (TPDOs 3 are synchronous PDOs)
• Emergency: producer
• RTR: supported only for node guarding/life guarding
• Heartbeat: consumer and producer
1.2
Abbreviations used in this Manual
Abbreviations
CAN
Controller area network
CHGND
chassis ground / earth ground
COB
Communication object
FSA
Finite state automaton
FSM
Finite state machine
NMT
Network management
ID
Identifier
LSB
Least significant bit
MSB
Most significant bit
PDO
Process data object
PDS
Power drive system
RPDO
Receive process data object
SDO
Service data object
TPDO
Transmit process data object
EMCY
Emergency object
rw
Read and write
ro
Read only
hm
Homing mode
pp
Profile position mode
pv
Profile velocity mode
vm
Velocity mode
Table 1: Abbreviations used in this Manual
1.3
Firmware Update
The software running on the microprocessor consists of two parts, a boot loader and the CANopen
firmware itself. Whereas the boot loader is installed during production and testing at TRINAMIC and
remains untouched throughout the whole lifetime, the CANopen firmware can easily be updated by the
user. The new firmware can be loaded into the module via the firmware update function of the TMCL-IDE,
using the USB interface of the module.
©2019 TRINAMIC Motion Control GmbH & Co. KG, Hamburg, Germany
Terms of delivery and rights to technical change reserved.
Download newest version at