TMCM-1160 CANopen® Firmware Manual • Firmware Version V3.20 | Document Revision V2.10 • 2019-JAN-04
32 / 110
4.2
Detailed Object Specifications
4.2.1
Object 2000
h
: Microstep Resolution
This object sets the microstep resolution of the drive. A value of 8 selects 256 (
2
8
) microsteps per full step.
Object Description
Index
Name
Object Type
Data Type
2000
h
Microstep Resolution
Variable
UNSIGNED8
Table 53: Object Description (2000
h
)
Entry Description
Sub-index
Access
PDO Mapping
Value Range
Default Value
0
rw
no
0. . . 8
8
Table 54: Entry Description (2000
h
)
4.2.2
Object 2001
h
: Fullstep Resolution
This object sets the fullstep resolution of the motor connected to the drive. Its default value is 200 because
most motors are 1.8° motors.
Object Description
Index
Name
Object Type
Data Type
2001
h
Motor full step resolution
Variable
UNSIGNED16
Table 55: Object Description (2001
h
)
Entry Description
Sub-index
Access
PDO Mapping
Value Range
Default Value
0
rw
no
0. . . 65535
200
Table 56: Entry Description (2001
h
)
4.2.3
Object 2002
h
: Brake Delay Times
With this object the delay times for applying and releasing an (optional) brake can be defined. Please see
also object 200Ah for an additional delay between enabling the power stage and releasing the brake. Both
times are given in ms.
©2019 TRINAMIC Motion Control GmbH & Co. KG, Hamburg, Germany
Terms of delivery and rights to technical change reserved.
Download newest version at