TMCM-1160 CANopen® Firmware Manual • Firmware Version V3.20 | Document Revision V2.10 • 2019-JAN-04
37 / 110
Entry Description
Sub-index
Access
PDO Mapping
Value Range
Default Value
0
rw
no
0. . . 13
0
Table 73: Entry Description (2085
h
)
4.2.11
Object 2086
h
: Pulse Divisor
Use this object to define the pulse divisor when internal units are selected for velocity and acceleration.
Writing to this object is only possible in SWITCHED_ON_DISABLED state. The velocity pre-scaler should be
decremented or incremented carefully (in steps of one).
Object Description
Index
Name
Object Type
Data Type
2086
h
Ramp Divisor
Variable
UNSIGNED8
Table 74: Object Description (2086
h
)
Entry Description
Sub-index
Access
PDO Mapping
Value Range
Default Value
0
rw
no
0. . . 13
0
Table 75: Entry Description (2086
h
)
4.2.12
Object 2087
h
: Maximum Velocity
The functionality of this object depends on the unit selection (refer to object
• If internal units are selected this object will be set to the fixed value of 2047 and cannot be changed.
• If user units are selected the maximum velocity (RPM or PPS) that is to be used must be set here. A
lower value in this object leads to a better accuracy of the unit conversion.
This value can only be changed when the drive is in SWITCHED_ON_DISABLED state.
Object Description
Index
Name
Object Type
Data Type
2087
h
Ramp Divisor
Variable
UNSIGNED32
Table 76: Object Description (2087
h
)
©2019 TRINAMIC Motion Control GmbH & Co. KG, Hamburg, Germany