TMCM-1160 CANopen® Firmware Manual • Firmware Version V3.20 | Document Revision V2.10 • 2019-JAN-04
73 / 110
6.1.14
Object 6083
h
: Profile Acceleration
This object indicates the configured acceleration. Object 6083
h
sets the maximum acceleration to be used
in profile position and profile velocity mode.
The units for object 6083
h
can be choosen with object 208E
h
, described in section
Object Description
Index
Name
Object Type
Data Type
6083
h
Profile Acceleration
Variable
SIGNED32
Table 216: Object Description (6083
h
)
Entry Description
Sub-index
Access
PDO Mapping
Value Range
Default Value
0
rw
no
SIGNED32
0
Table 217: Entry Description (6083
h
)
6.1.15
Object 6084
h
: Profile Deceleration
This object indicates the configured deceleration. On the TMCM-1160 module the deceleration ramp is
always the same as the acceleration ramp. For this reason this object is a read-only object and always
reads the same value as object
Object Description
Index
Name
Object Type
Data Type
6084
h
Profile Deceleration
Variable
SIGNED32
Table 218: Object Description (6084
h
)
Entry Description
Sub-index
Access
PDO Mapping
Value Range
Default Value
0
ro
no
SIGNED32
0
Table 219: Entry Description (6084
h
)
6.1.16
Object 6085
h
: Quick Stop Deceleration
This object indicates the configured deceleration used to stop the motor when the quick stop function is
activated and the quick stop code object 605A
h
is set to 2 (or 6). The value is given in the same unit as
profile acceleration object 6083
h
.
©2019 TRINAMIC Motion Control GmbH & Co. KG, Hamburg, Germany
Terms of delivery and rights to technical change reserved.
Download newest version at