4.2.40
Object 2702
h
: Device Digital Inputs
Bits 23. . . 16 of this object reflect the states of the general purpose inputs of the module. The number of
available inputs depends on the module type.
Bit Definitions
Bit
Description
16
IN0
17
IN1
Table 133: Bit Definitions (2702
h
)
Object Description
Index
Name
Object Type
Data Type
2702
h
Device Digital Inputs
Variable
UNSIGNED32
Table 134: Object Description (2702
h
)
Entry Description
Sub-index
Access
PDO Mapping
Value Range
Default Value
0
ro
yes
–
0
Table 135: Entry Description (2702)
h
4.2.41
Object 2703
h
: Device Digital Outputs
With this object the digital outputs (general purpose outputs) can be set. Bits 23. . . 16 of sub index 1 switch
the outputs of the module. Bits 23. . . 16 of sub index 2 determine which outputs can be switched. The
number of available digital outputs depends on the module type.
Bit Definitions
Bit
Description
16
OUT0
17
OUT1
Table 136: Bit Definitions (2703
h
)
Object Description
Index
Name
Object Type
Data Type
2703
h
Device Digital Outputs
Variable
ARRAY
Table 137: Object Description (2703
h
)
©2019 TRINAMIC Motion Control GmbH & Co. KG, Hamburg, Germany